Common Faults and Solutions of Automatic Labeling Machine

时间:2019/3/25 9:04:22

In the process of using the automatic labeling machine, there are always more or less problems, and there are three common faults. Here we share with you how to solve these three kinds of labeling machine faults quickly and effectively.

1. Wrinkle treatment after labeling:

(1) Bid delivery rate is faster than the surface linear rate of material operation, so it is enough to adjust the bid delivery rate.

(2) If the bid is issued too early, the electro-eye of the object can be moved to the right.

(3) Pre-bid label is too long, just adjust the length of pre-bid.

(4) The speed of labeling is not fast enough, just raise the speed of labeling.

2. The labeling machine can not be labeled.

(1) If the bidding rate is too slow, it is enough to increase the bidding rate.

(2) The position of the electro-eye of the object is not right, so the position of the electro-eye of the object can be adjusted.

(3) The advance label is not long enough, and the length of the reserved label can be adjusted.

(4) The object electro-eye is too far away from the mark end, so move the object electro-eye to the right.

(5) Material has not been detected by the electro-optic device, so it is enough to adjust the electro-optic device.

(6) The spacing between materials is too small to increase the spacing between materials.

3. Processing method of labeling machine without labeling:

(1) The position of the electro-eye of the object is not right, so the position of the electro-eye of the object can be adjusted.

(2) If the electro-ophthalmic device fails, the electro-ophthalmic device can be replaced.

(3) Label with label is not enough to pull paper, just adjust the pull paper tightly.

(4) The color of the patch can not be sensed by the electro-eye, so it is enough to replace the electro-eye with the appropriate model function.

(5) If the marker is not opened, the marker can be opened.

4. The reasons for not being able to sense are usually as follows:

(1) The sensitivity of the induction switch needs to be adjusted. Solution: Sensitivity needs to be adjusted

(2) The induction switch is not suitable for the measured object. Solution: Replace the induction switch.

(3) Causes caused by control systems, such as program control. Specifically according to the relevant circuit. Of course, if there are other objects that can be tested, this can be ruled out.